The ticket reads like a config problem. A 100G link between two aggregation switches has been up for fourteen months. Last Tuesday a contractor re-terminated a patch panel two floors away, and since then the port drops for 30 to 90 seconds, comes back on its own, and drops again a few hours later. No CRC storm, no FEC alarm, nothing in the log but link down and link up. The customer's first instinct is "the switch is bad"; the second is "the new module is bad."
Both are usually wrong. What changed was the fiber path, and on an LR4 link the fiber path announces itself in a very specific way. The trick is reading the evidence in the right order.

What LR4 Is Doing on That Strand
100GBASE-LR4, defined in Clause 88 of IEEE 802.3ba, carries 100 Gb/s as four lanes of 25.78125 Gb/s NRZ. The four lanes are LAN-WDM wavelengths - 1295.56, 1300.05, 1304.58, and 1309.14 nm - multiplexed inside the module onto a single duplex LC pair. Reach is 10 km over OS2 at 0.4 dB/km, and the standard allocates 6.3 dB of maximum insertion loss for the whole channel, connector and splice losses included. The specified error rate is 1×10⁻¹² at the MAC/PLS service interface, and the standard does not require FEC to get there.
That last part matters. The link is engineered against a 1×10⁻¹² target, not a forward-error-correction cliff, so a channel with 5.8 dB of loss against a 6.3 dB budget does not sit at "slightly worse BER." It sits one dirty connector away from losing the light entirely.
The First Fork: Correlated or Uncorrelated
Four wavelengths share one fiber in each direction. This single fact splits the diagnosis in half, and it does so in about thirty seconds.
If all four receive lanes degrade together, the cause is on the common path outside the module: a contaminated end face, a cracked patch cord, a pinched bundle, a bad panel adapter, a marginal splice. If one lane degrades while the other three stay flat, the common path is healthy and the fault is inside the module - a laser, a TOSA lane, a mux leg - or in that lane's host electronics.
Do not skip this fork. Engineers who jump to cleaning spend two hours on a link with a dying lane-2 laser; engineers who jump to RMA ship back a good optic and keep the contaminated panel.
Read the Instrument, Not the Alarm
Digital diagnostics are the only witness you have, and they must be read at the moment of failure. Once the port recovers, every value is back to normal and the module looks innocent.
|
Reading |
Where it comes from |
What it discriminates |
|
Tx power, per lane |
Near-end module |
Laser degradation, bias drift, one dead mux leg |
|
Rx power, per lane |
Near-end module |
Plant loss, contamination, bend loss, far-end laser |
|
Bias current, per lane |
Near-end module |
Aging laser working harder for the same output |
|
Case temperature |
Both ends |
Thermal margin, airflow, adjacent-port heating |
|
Pre-FEC BER and corrected blocks |
Host port counters |
Margin erosion that has not dropped the link yet |
|
Link-down reason |
Host PHY log |
Loss of signal versus loss of block lock |
Most platforms poll optics every 10 to 60 seconds, longer than a flap. Set optical alarm thresholds one to two dB inside the normal window and point them at syslog, so the module reports distress before it goes dark. If your only record is "link down at 14:07," you are investigating a rumour.

The Ladder
Work in this order; each step either bounds the fault or eliminates a layer, and none needs a maintenance window.
Classify the failure. Check the PHY log: loss of signal, or loss of block lock with errors first? LOS points at power; block lock errors point at signal quality or a FEC mismatch.
Snapshot both ends. Poll Tx and Rx per lane at one-second intervals on both modules and correlate with the drop timestamp. Two minutes of logging beats an hour of guessing.
Apply the fork. All four lanes down together means plant; one lane means module.
Inspect, clean, inspect again. Do it to IEC 61300-3-35. "Re-seating" a connector redistributes contamination instead of removing it. A dirty end face attenuates and reflects, and light reflected back into an EML destabilises the laser that produced it.
Measure the channel, do not estimate it. Light source and power meter, reference first, then every segment including panel adapters. Compare the total against 6.3 dB. A link within half a dB of budget will flap forever and test "fine" every time someone looks at it.
Hunt the mechanical fault. Bend radius at the tray entry, cable ties cinched onto the boot, a tray door resting on the bundle, a patch cord hanging from its own weight. Such loss changes with temperature and with whoever last opened the cabinet - the signature of a link that fails at 3 p.m. and recovers overnight.
Swap one element at a time. Known-good patch cord, then far-end module, then near-end module. Bounding beats replacing.
Three Traps That Impersonate Dirty Fiber
FEC asymmetry. If one end runs RS(544,514) and the other does not, the link normally refuses to come up at all rather than flapping - but an auto-negotiated mismatch can produce exactly this cycling. Check both ends before you clean anything.
Thresholds set by template. A module inherits alarm thresholds from another reach or another vendor's profile. The link is healthy; the alarm is wrong. Compare configured thresholds against the standard's per-lane limits, not against another port's numbers.
Temperature, not optics. A blocked fan tray or a densely packed neighbour can push an LR4 past its case temperature range. Thermal shutdown looks identical to a fiber fault in the log; DDM temperature at the failure timestamp separates them at a glance.
Key Takeaways
Four wavelengths on one fiber means correlated lane behaviour points at the plant, isolated behaviour at the module. Use that fork first.
A 1×10⁻¹² link on a 6.3 dB budget has no FEC cliff to hide behind; margin near the limit shows up as flapping, not degradation.
Capture DDM at the moment of failure; post-recovery readings are why "the optics test fine" gets repeated for weeks.
Clean and inspect to IEC 61300-3-35, then measure the channel against budget with a meter. Cleaning without measuring leaves the actual margin unknown.
Mechanical stress and thermal cycling produce intermittent loss with a daily rhythm. If the flap has a time-of-day pattern, look at the tray before the transceiver.